Uniform heating throughout the hall. TEC CV fibreglass heat exchangers, ranging from 30 to 90 kW, operated by the Tecsisel control system.
The built-in fan, with a capacity of 3,000 to 9,000 m³/h, distributes the heat evenly throughout the hall.
The hot water passes through the heat exchanger and heats the air in the hall with high energy efficiency.
The fibreglass construction means the heat exchanger can be washed with a high-pressure jet between cycles.
The control system activates the heating based on the temperature measured in the hall.
| Model | TEC CV 30 | TEC CV 60 | TEC CV 75 | TEC CV 90 | |
|---|---|---|---|---|---|
| *Engine | kW | 0,11 | 0,26 | 0,36 | 0,47 |
| V | 3 x 400 | 3 x 400 | 3 x 400 | 3 x 400 | |
| rpm | 900 | 900 | 900 | 900 | |
| Heat output | kW | 30 | 60 | 75 | 90 |
| Fan flow rate | m³/h | 3.000 | 6.000 | 7.500 | 9.000 |
| Dimensions | A (cm) | 75 | 78 | 80 | 87,5 |
| Ø (cm) | 70 | 100 | 110 | 110 | |
| B (cm) | 35 | 35 | 37,5 | 45 | |
| P (") | 1" | 1" 1/2 | 1" 1/2 | 2" | |
*It can be manufactured in other voltages and frequencies