Evaporative cooling for hot days. Tecsisel cooling panels and high-pressure misting systems, operated by the control system.
TEC CP 150 panels, 90, 150 or 200 cm high, mounted on TEC CL 150 aluminium rails.
Pumps with flow rates of 4 to 25 L/min at 70 bar supply stainless steel injectors fitted with ceramic orifices.
The control system activates the cooling system in conjunction with the ventilation, depending on the temperature and humidity in the hall.
Side cooling system with air control chamber, protected by patent no. 10516.
Aluminium channels
| Model | TEC CL 150 | |
|---|---|---|
| Dimensions | L (cm) | 15 |
| C (cm) | 600 | |
Cooling panel
| Model | TEC CP 150 | |
|---|---|---|
| Dimensions | A (cm) | 90 / 150 / 200 |
| L (cm) | 15 | |
| C (cm) | 30 | |
High-pressure pumps
| Model | TEC BP 4 | TEC BP 6 | TEC BP 12 | TEC BP 15 | TEC BP 21 | TEC BP 25 | |
|---|---|---|---|---|---|---|---|
| *Engine | kW | 1,1 | 1,5 | 3 | 4 | 5,5 | 7,5 |
| V | 3 x 400 | 3 x 400 | 3 x 400 | 3 x 400 | 3 x 400 | 3 x 400 | |
| Pressure | bar | 70 | 70 | 70 | 70 | 70 | 70 |
| Flow rate | L/min | 4 | 6 | 12 | 15 | 21 | 25 |
*It can be manufactured in other voltages and frequencies
Stainless steel injectors
| Model | TEC IJ 15 | TEC IJ 20 | TEC IJ 30 | |
|---|---|---|---|---|
| Ø Orifice (ceramic) | mm | 0,15 | 0,20 | 0,30 |
| Flow rate | ml/min | 37 | 64 | 100 |
Stainless steel tube
| Model | TEC INX | |
|---|---|---|
| Technical specifications | Ø (mm) | 12 |
| Thickness (mm) | 1,5 | |